Data sheet Cisco public
© 2025 Cisco and/or its affiliates. All rights reserved.
Table 13. BTU details for Catalyst 9500 power supplies (BTU/hr)
Total output BTU
(Note: 1000
BTU/hr = 293W)
- Model
C9K-PWR-
1600WAC-R
C9K-PWR-
1600WDC-R
C9K-PWR-
650WAC-R
C9K-PWR-
650WACL-R
C9K-PWR-
930WDC-R
PWR-C4-
950WAC-R
PWR-C4-
950WDC-R
C9500-32C
3,631
3,709
–
–
–
–
–
C9500-32QC
–
–
1,815
1,815
1,856
–
–
C9500-48Y4C
–
–
1,856
1,856
1,856
–
–
C9500-24Y4C
–
–
1,454
1,454
1,484
–
–
C9500-16X with
10G NM
–
–
–
–
–
941
967
C9500-16X with
40G NM
–
–
–
–
–
904
930
Table 14 shows the power supplies supported in the Cisco Catalyst 9500 Series Switches.
Table 14. Catalyst 9500 power supply matrix
Model
C9K-PWR-
1600WAC-R
C9K-PWR-
1600WDC-R
C9K-PWR-
650WAC-R
C9K-PWR-
650WACL-R
C9K-PWR-
930WDC-R
PWR-C4-
950WAC-R
PWR-C4-
950WDC-R
C9500-32C
Yes
Yes
No
No
No
No
No
C9500-32QC
No
No
Yes
Yes
Yes
No
No
C9500-48Y4C
No
No
Yes
Yes
Yes
No
No
C9500-24Y4C
No
No
Yes
Yes
Yes
No
No
C9500-16X
No
No
No
No
No
Yes
Yes
Table 15 shows key differences between the C9K-PWR-650WAC-R and C9K-PWR-650WACL-R power supplies.
Table 15. Key differences between the C9K-PWR-650WAC-R and C9K-PWR-650WACL-R
Criteria
C9K-PWR-650WAC-R
C9K-PWR-650WACL-R
IEC-61000-4-5 surge
4KV CM, 2KV DM
2.5KV CM, 1KV DM
AC line hold-up time
=20 ms at 90% load
=12 ms at 100% load
Over Power Protection (OPP)
130% x rated load
140% x rated load