/mcpError Message %UC_CWLCSS-4-SwitchesAndAccessPointReached95PercentCapacity: %[Reason=String] [AppID=String][ClusterID=String][NodeID=String]: The current record count for switches and access points has reached 95%. The maximum capacity is 50000. Explanation The current record count for switches and access points has reached 95%. The maximum capacity is 50000. Recommended Action Please review number of switches and access points and their activation status. Ensure the count is kept below this threshold to avoid service shutdown. Error Message %UC_CWLCSS-1-CiscoWLCSyncServiceDown: %[Reason=String][AppID=String][ClusterID=String] [NodeID=String]: Reached maximum record count for Switches and Access Points. The maximum capacity is 50000. Explanation Exceeded maximum number of devices in the Switches and Access points. The maximum capacity is 50000. Recommended Action You need to review current set of switches and access points for their activation status. Delete unused devices to ensure sufficient capacity and restart service. Error Message %UC_CWLCSS-6-CiscoWLCSyncStarted: %[Reason=String][AppID=String][ClusterID=String] [NodeID=String]: Cisco WLC Synchronization service successfully started. Explanation Application successfully started. Recommended Action No action required. Error Message %UC_CWLCSS-6-CiscoWLCSyncStartFailure: %[Reason=String][AppID=String][ClusterID=String] [NodeID=String]: Cisco WLC Synchronization service failed to start. Explanation Error occurred while starting application. Recommended Action See application logs for error, may require restarting the application. Error Message %UC_CWLCSS-3-CiscoWLCSyncDBAccessFailure: %[Reason=String][AppID=String] [ClusterID=String][NodeID=String]: CiscoWLCSync process failed to access local database. Explanation CiscoWLCSync failed to access local database. Recommended Action Please make sure the local CallManager database is working properly. The failed sync process will restart at the next scheduled time. Error Message %UC_CWLCSS-3-CiscoWLCSyncDBInsertFailure: %[Reason=String][AppID=String][ClusterID=String] [NodeID=String]: CiscoWLCSync process cannot insert a new record. Explanation Exceeded maximum number of devices in the Switches and Access points. Recommended Action You need to review current set of switches and access points for their activation status. Delete unused devices to ensure sufficient capacity. 5/24/26, 3:34 AM System Error Messages for Cisco Unified Communications Manager 15 - Cisco https://www.cisco.com/c/en/us/td/docs/voice_ip_comm/cucm/err_msgs/15_x/ccmalarms15.html 306/343