/mcpComments Operations Data Type Parameter AfterMessageAction can only accept integer with value 1, 2, 4, 6, 8 Values can be: • 1: Hang up • 2. for other actions with object id (call handler, interview handler, directory handler) • 4. Take Message • 6. Restart greeting • 8: Route from next call routing rule. Read/Write Integer(2) AfterGreetingAction The unique identifier of the CallAction object that determines what action Cisco Unity Connection will take on the call after the greeting is played. Read/Write String(36) AfterGreetingActionObjectId The name of the conversation to which the caller is routed. Read/Write String(64) AfterGreetingTargetConverstion The unique identifier of the specific object to send along to the target conversation. Read/Write String(36) AfterGreetingTargetHandlerObjectId A flag indicating whether the "Record your message at the tone…" prompt prior to recording a message. Values can be: • 0: System will not play the "Record your message at the tone…" prompt prior to recording a message. • 1: System will play the "Record your message at the tone…" prompt prior to recording a message. Default Value: 1 Read/Write Integer(2) PlayRecordMessagePrompt Cisco Unity Connection Provisioning Interface (CUPI) API 55 Cisco Unity Connection Provisioning Interface (CUPI) API -- User Greetings Explanation of Data Fields